Overhead Transmission Conductor
Full range of overhead conductors and aerial insulated cables for transmission and distribution lines up to extra-high voltage. Manufactured to GB/T 1179-2017, GB/T 12527-2008, GB/T 14049-2008 and Q/GDW 176-2008. Approved supplier for State Grid & Southern Grid projects.
- ACSR (JL/G1A) 10/2 – 1250/100 mm², including large-section UHV variants
- Heat-resistant conductor JNRLH1/LB20A up to 1250/100 mm²
- XLPE insulated aerial cable 1 kV / 10 kV, single-core & bundled (2-core, 4-core, ABC)
- Conductor material: AA-grade electrical aluminum, LY9 duralumin, LB20A aluminum-clad steel
- Insulation: weather & UV-resistant cross-linked polyethylene (XLPE)
- Custom cross-sections, voltage classes and lengths available on request
Conductor & Overhead Insulated Cable Products
ACSR, XLPE insulated overhead cables, heat-resistant conductors and bundled cables — Click any photo to enlarge

ACSR Conductor
Aluminum Conductor Steel Reinforced for overhead transmission lines.

ACSR UHV Large Cross-Section
Extra-high-voltage ACSR conductor with large cross-section.

Heat-Resistant Conductor
Aluminum-clad steel core heat-resistant aluminum-alloy stranded conductor.

XLPE ACSR 10kV 1×240-30
Single-core ACSR conductor, XLPE insulated overhead cable, 10kV.

XLPE ACSR 1kV 1×70-10
Single-core ACSR conductor, XLPE insulated overhead cable, 1kV.

XLPE Overhead 1×240mm²
Single-core aluminum conductor, XLPE insulated overhead cable.

XLPE Overhead 1×70mm²
Single-core aluminum conductor, XLPE insulated overhead cable.

Bundled 2×35mm²
Two-core parallel-bundled overhead insulated cable, XLPE.

Bundled 4×70mm²
Four-core parallel-bundled overhead insulated cable, XLPE.
Aluminum Wire & Overhead Insulated Cable — Specifications
Sample-model parameter table from the factory catalog. Custom sizes and specs available on request.
| Specification | Aluminum Conductor JL/G1A 300/40-24/7 |
Aluminum Conductor JL1/G1A 1250/100-84/19 |
Heat-Resistant Conductor JNRLH1/LB20A 720/50-45/7 |
Parallel Bundle BS3-JKLYJ 0.6/1kV 2×35 |
Parallel Bundle BS-JKLYJ 0.6/1kV 4×70 |
Aerial Insulated JKLYJ 1kV 1×70 |
Aerial Insulated JKLYJ 10kV 1×240 |
Aerial Insulated (ACSR core) JKLGYJ 1kV 1×70/10 |
Aerial Insulated (ACSR core) JKLGYJ 10kV 1×240/30 |
|---|---|---|---|---|---|---|---|---|---|
| Conductor CSA Range (mm²) | 10/2 – 1250/100 | 10/2 – 1250/100 | 70/10 – 1250/100 | Single-core: 10 – 120 | Single-core: 10 – 120 | 10 – 400 | 35 – 400 | 10/2 – 240/30 | 10/2 – 240/30 |
| Sample Conductor CSA | Al 300 / Steel 40 | Al 1250 / Steel 100 | Al 720 / Al-clad Steel 50 | 2 × 35 mm² | 4 × 70 mm² | 70 mm² | 240 mm² | Al 70 / Steel 10 | Al 240 / Steel 30 |
| Outer Diameter | 23.90 mm | 47.90 mm | 36.20 mm | 2 × 9.40 mm | 4 × 14.10 mm | 12.80 mm | 26.50 mm | 12.50 mm | 28.50 mm |
| Conductor Material | High-conductivity duralumin + Class-A galvanized steel | LY9 duralumin + Class-A galvanized steel | Heat-resistant aluminum alloy + LB20A aluminum-clad steel | AA-grade electrical aluminum | AA-grade electrical aluminum | Hard aluminum (1060 / 1370 etc.) | Hard aluminum (1060 / 1370 etc.) | Electrical aluminum + high-strength steel wire | Electrical aluminum + high-strength steel wire |
| Insulation Material | None (bare) | None (bare) | None (bare) | Weather / UV-resistant XLPE | Weather / UV-resistant XLPE | Weather / UV-resistant XLPE | Weather / UV-resistant XLPE | Weather / UV-resistant XLPE | Weather / UV-resistant XLPE |
| Rated Voltage | — | — | — | U₀/U = 0.6/1 kV | U₀/U = 0.6/1 kV | 1 kV | 10 kV | 1 kV | 10 kV |
| Breaking Force | ≥ 92.36 kN | ≥ 299.80 kN | ≥ 288.60 kN | ≥ 7.52 kN | ≥ 70.38 kN | ≥ 10.35 kN | ≥ 34.68 kN | ≥ 23.36 kN | ≥ 75.19 kN |
| DC Resistance @ 20°C | ≤ 0.094 Ω/km | ≤ 0.023 Ω/km | ≤ 0.048 Ω/km | ≤ 1.200 Ω/km | ≤ 0.443 Ω/km | ≤ 0.443 Ω/km | ≤ 0.125 Ω/km | ≤ 0.422 Ω/km | ≤ 0.118 Ω/km |
| Compliance Standard | GB/T 1179-2017 | GB/T 1179-2017 | GB/T 1179-2017, NB/T 42060-2015 | Q/GDW 176-2008 | Q/GDW 176-2008 | GB/T 12527-2008 | GB/T 14049-2008 | Enterprise std. QJ/DS02.03-2023 | Enterprise std. QJ/DS02.03-2023 |
| Notes | All sample models above are stock-item references. Custom cross-sections, voltage classes, insulation types and lengths available on request — send your specification. | ||||||||
Where These Conductors Are Used
High-Voltage Transmission
ACSR & UHV large-section conductors for 110 kV – 1000 kV overhead lines.
Urban Distribution Grid
XLPE insulated aerial cables for 1 kV – 10 kV city and township networks.
Rural Electrification
Bundled 2-core / 4-core cable for low-voltage rural lines and last-mile service drops.
Heat-Loading Routes
Heat-resistant alloy conductor for lines that must carry higher ampacity in summer peaks.
Request Conductor Pricing & Samples
Send model, cross-section, voltage class and quantity — reply within 24 hours.